EMI/EMC
Sechan operates an on-site test facility for determining compliance to MIL-STD-461 and MIL-STD-462. The facility is based on a 12' x 20' x 8' RFI/EMI room which exceeds -120dB attenuation and meets the requirements of MIL-STD-285 and NSA 65-6 for shielding effectiveness through the range 1kHz to 10GHz. This capability provides a repeatable and readily-available facility for design verification and production quality audits, while removing the schedule and technical risks inherent in subcontracting this effort.

  • MIL-STD-461/462 EMI Capabilities
  • Conducted Emissions (CE)
  • Radiated Emissions (RE)
  • Conducted Susceptibility (CS)
  • Radiated Susceptibility (RS)
  • Magnetic Fields (MIL-STD-1399)
  • Power Source Simulation (AC & DC)


MIL-STD-461/462 TESTS

TEST DESCRIPTION MIL-STD-461 C
REQUIREMENT
MIL-STD-461 D/E
REQUIREMENT
Conducted Emission CE01: 30Hz-15kHz
CE03: 15kHz-50MHz
CE06
CE07
CE101: 30Hz-10kHz
CE102:10kHz-10MHz
CE106
Conducted Susceptibility CS01: 30Hz-50kHz
CS02
CS03
CS04
CS05
CS06
CS101: 30Hz-50kHz
CS103
CS104
CS105
CS114
CS115
CS116
Radiated Emission RE01: 30Hz-50kHz
RE02: 14kHz-10GHz
RE101: 30Hz-100kHz
RE102: 14kHz-18GHz
Radiated Susceptibility RS01: 30Hz-30kHz
RS02
RS03: 14kHz-10GHz
RS103
Magnetic Susceptibility RS06  


Sechan Electronics, Inc. :: 525 Furnace Hills Pike, Lititz, PA 17543-8954
Phone: 717.627.4141 :: Fax: 717.627.4144 :: sales@sechan.com